Advantech EKI-1528 Manuel d'utilisateur Page 1

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Passerelles/contrôleurs Advantech EKI-1528. Advantech EKI-1528 User manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 92
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
User Manual
EKI-1528/1526
8/16-port RS-232/422/485 Serial
Device Server
Vue de la page 0
1 2 3 4 5 6 ... 91 92

Résumé du contenu

Page 1 - EKI-1528/1526

User ManualEKI-1528/15268/16-port RS-232/422/485 Serial Device Server

Page 2 - Product Warranty (2 years)

EKI-1528/1526 User Manual 41.3.5 General LED Indicators:– System: Power, System Status– LAN: Speed, Link/Active– Serial: Tx, Rx Alert Tool: Built-in

Page 3 - Declaration of Conformity

Chapter 22 Getting Started

Page 4 - Safety Instructions

EKI-1528/1526 User Manual 62.1 Understanding the EKI-1528/1526The EKI-1528/1526 is network-based, serial device server for connecting RS-232/422/485 s

Page 5

7 EKI-1528/1526 User ManualChapter 2 Getting Started2.1.1 COM Port Redirector (Virtual COM)Advantech serial device server configuration utility is a s

Page 6

EKI-1528/1526 User Manual 82.1.2 TCP Server (Data Mode)In the TCP server mode, you might initiate the TCP connection from host to the EKI-1500 serial

Page 7 - Chapter 1

9 EKI-1528/1526 User ManualChapter 2 Getting Started2.1.3 TCP Client (Data Mode)In the TCP Client mode, the TCP connection will be established from th

Page 8 - 1.2 Features

EKI-1528/1526 User Manual 102.1.5 UDP Mode (Data Mode)UDP is used primarily for broadcasting messages over a network. In the UDP servermode, the EKI-1

Page 9 - Chapter 1 Introduction

11 EKI-1528/1526 User ManualChapter 2 Getting Started2.2 HardwareIn this section, it will give you an overview of the EKI-1528/1526 hardware andinstal

Page 10 - 1.4 Package Checklist

EKI-1528/1526 User Manual 122.2.2 LED IndicatorsThere are LEDs display the power status, system status, dual Ethernet networks sta-tus, and serial com

Page 11 - Chapter 2

13 EKI-1528/1526 User ManualChapter 2 Getting Started2.3 Connecting HardwareThis section introduces how to connect the EKI-1528 or EKI-1526 to serial

Page 12 - EKI-1528/1526 User Manual 6

EKI-1528/1526 User Manual iiCopyrightThe documentation and the software included with this product are copyrighted 2008by Advantech Co., Ltd. All righ

Page 13 - Chapter 2 Getting Started

EKI-1528/1526 User Manual 142.3.2 Connecting EKI-1528/1526’s PowerConnect the EKI-1528 or EKI-1526 AC power line with its AC connector. If the poweris

Page 14 - 2.1.2 TCP Server (Data Mode)

15 EKI-1528/1526 User ManualChapter 2 Getting Started2.4 Installing the Configuration UtilityThe following section will show you how to install the Ad

Page 15

EKI-1528/1526 User Manual 165. The Setup program will specify a default installation path: C:\Program Files\Advantech eAutomation\Serial Device Server

Page 16 - 2.1.6 Control Mode

Chapter 33 Configuration

Page 17

EKI-1528/1526 User Manual 183.1 Configuration Utility OverviewEKI-1500 serial device servers provide an easy-to-use utility to configure your seriald

Page 18 - 2.2.3 Dimensions (Unit: mm)

19 EKI-1528/1526 User ManualChapter 3 Configuration3.2 Discovering Serial Device Servers3.2.1 Auto SearchingAdvantech Serial Device Server Configurati

Page 19

EKI-1528/1526 User Manual 20Select the device in this sub-tree. The first tab on the “Configuration Area” shows thesummary of “Basic Information” incl

Page 20 - RS-485Data-Data+--GND

21 EKI-1528/1526 User ManualChapter 3 Configuration3.2.2 Clear Device List and Search AgainYou can click the button on the Quick Tool Bar. The utili

Page 21

EKI-1528/1526 User Manual 223.2.3 Manual AppendingUsing “Add IP address to Favorite” or “Search a Range of IP addresses” function,you are able to add

Page 22 - EKI-1528/1526 User Manual 16

23 EKI-1528/1526 User ManualChapter 3 Configuration3.3 Network SettingsThis section explains how to configure the EKI-1528/1526 network using this uti

Page 23 - Chapter 3

iii EKI-1528/1526 User Manual Declaration of ConformityCEThis product has passed the CE test for environmental specifications when shieldedcables are

Page 24 - EKI-1528/1526 User Manual 18

EKI-1528/1526 User Manual 24DHCP + Auto-IPDHCP Server assigned IP address, Subnet Mask, Default Gateway, and DNS.BOOTP + Auto-IPBOOTP Server assigned

Page 25 - Chapter 3 Configuration

25 EKI-1528/1526 User ManualChapter 3 Configuration Description: You can give a more detailed description on the function of the port for easier man-

Page 26 - EKI-1528/1526 User Manual 20

EKI-1528/1526 User Manual 26 Data Bits: The EKI-1500 serial device server provides four options: 5, 6, 7 and 8. Stop Bits: The EKI-1500 serial devic

Page 27

27 EKI-1528/1526 User ManualChapter 3 ConfigurationDelay Time (ms)When you enable the delay time, the serial port will postpone the received data fort

Page 28 - 3.2.3 Manual Appending

EKI-1528/1526 User Manual 283.5 Operation Mode Settings3.5.1 Virtual COM ModeThe EKI-1500 serial device server extends traditional COM ports of a PC t

Page 29

29 EKI-1528/1526 User ManualChapter 3 ConfigurationThere are two operating mode of Multi-access function. One is Normal mode;another is Round-Robin mo

Page 30 - 3.4 Serial Settings

EKI-1528/1526 User Manual 30You might select “USDG Mode” as the following figure to change the mode of the portto TCP server/client or UDP mode.Protoc

Page 31

31 EKI-1528/1526 User ManualChapter 3 ConfigurationData Idle TimeoutThe default is 60 seconds. If you want to keep connection continually, you candisa

Page 32 - EKI-1528/1526 User Manual 26

EKI-1528/1526 User Manual 32Peer NumberSet the number of network device which you want to connect. You can set maximumsixteen network devices which yo

Page 33

33 EKI-1528/1526 User ManualChapter 3 ConfigurationThe default value is 1000 ms.Example: <Guard Time> + <Guard Time> + <Guard Time>

Page 34 - 3.5 Operation Mode Settings

EKI-1528/1526 User Manual ivSafety Instructions1. Read these safety instructions carefully.2. Keep this User Manual for later reference.3. Disconnect

Page 35

EKI-1528/1526 User Manual 343.6 Accessible IP SettingsAccessible IP setting allows you to add or remove the blocking host IP addresses toprevent unaut

Page 36 - EKI-1528/1526 User Manual 30

35 EKI-1528/1526 User ManualChapter 3 Configuration3.7.2 SNMP TrapYou need to set the proper IP address of SNMP Trap Server. And choose the TrapVersio

Page 37

EKI-1528/1526 User Manual 36Warm StartThis refers to restarting the system without turning the power off. When performing awarm start, the EKI-1528/15

Page 38 - EKI-1528/1526 User Manual 32

37 EKI-1528/1526 User ManualChapter 3 ConfigurationDCD ChangeThe DCD (Data Carrier Detect) signal has changed, also indicating that the modemconnectio

Page 39

EKI-1528/1526 User Manual 383.9 Administrator SettingsThe configuration utility provides several administrator settings for easy managementand configu

Page 40 - 3.7 Auto Warning Settings

39 EKI-1528/1526 User ManualChapter 3 Configuration3.9.2 Import/Export Serial Port SettingThe utility allows importing or exporting the serial port se

Page 41

EKI-1528/1526 User Manual 40Click “Unlock Device” to unlock the serial device sever, and you need to fill in thepassword you have set up before. If yo

Page 42 - 3.7.4 Serial Port Event

41 EKI-1528/1526 User ManualChapter 3 Configuration3.9.5 Restore to Factory Default SettingsThe configuration utility provides this function to let yo

Page 43

EKI-1528/1526 User Manual 423.9.6 Update FirmwareAdvantech continually upgrades its firmware to keep up with the ever-expendingworld of computing. You

Page 44 - 3.9 Administrator Settings

43 EKI-1528/1526 User ManualChapter 3 ConfigurationWait for few seconds to process the updating firmware. After downloading the firm-ware completely,

Page 45

v EKI-1528/1526 User Manual Chapter 1 Introduction...11.1 Overview ...

Page 46 - EKI-1528/1526 User Manual 40

EKI-1528/1526 User Manual 44

Page 47

Chapter 44 Setting COM Redirector

Page 48 - 3.9.6 Update Firmware

EKI-1528/1526 User Manual 464.1 Setting COM Redirector(Virtual COM port)Advantech COM port mapping software is a serial COM port redirector that creat

Page 49

47 EKI-1528/1526 User ManualChapter 4 Setting COM RedirectorThe COM ports in the “Virtual Com Ports” listing are now available for use by Win-dows app

Page 50 - EKI-1528/1526 User Manual 44

EKI-1528/1526 User Manual 484.1.2 Manual MappingRight click the serial device name on the sub-tree of Device Server List area andselect the “Manual Ma

Page 51 - Chapter 4

49 EKI-1528/1526 User ManualChapter 4 Setting COM RedirectorAuto Reconnect PropertySometimes, the connection between Advantech serial device server an

Page 52 - 4.1.1 Auto Mapping

EKI-1528/1526 User Manual 504.1.3 Manual Direct Mapping Virtual COM PortClick the button on the Quick Took bar, you can add a target by selecting th

Page 53 - 47 EKI-1528/1526 User Manual

51 EKI-1528/1526 User ManualChapter 4 Setting COM RedirectorGroup Remove PortRight click on Virtual Com Ports on Device Server List Area and select “G

Page 54 - 4.1.2 Manual Mapping

EKI-1528/1526 User Manual 52Click “Simple Serial Test” on the Tools menu,Select which COM port you want to run diagnostic test, and then press “Test”

Page 55 - 49 EKI-1528/1526 User Manual

53 EKI-1528/1526 User ManualChapter 4 Setting COM RedirectorSignal Test RTS -> CTS: check the RTS and CTS signal between two ports DTR -> RI:

Page 56 - EKI-1528/1526 User Manual 50

EKI-1528/1526 User Manual vi3.8 Port Monitor ... 373.9 Admini

Page 57 - 4.2 Running Diagnostic Test

EKI-1528/1526 User Manual 54

Page 58 - EKI-1528/1526 User Manual 52

Chapter 55 Web-Based Configuration

Page 59 - 53 EKI-1528/1526 User Manual

EKI-1528/1526 User Manual 565.1 OverviewEKI-1500 serial device server can be configured through a web interface. By using astandard web browser, the s

Page 60 - EKI-1528/1526 User Manual 54

57 EKI-1528/1526 User ManualChapter 5 Web-Based ConfigurationBy Windows Internet Explorer

Page 61 - Chapter 5

EKI-1528/1526 User Manual 585.3 SystemYou can change the Device Name and Device Description on this page. You can alsoenable or disable the Web, Telne

Page 62 - 5.2 Accessing the Web Page

59 EKI-1528/1526 User ManualChapter 5 Web-Based Configuration5.5 Port ConfigurationThere are Basic, Operation Mode, and Advanced Setting in the serial

Page 63 - By Windows Internet Explorer

EKI-1528/1526 User Manual 605.6 MonitorYou can monitor the serial ports settings, statistic, and the connected IP address byclick on Monitor function

Page 64 - 5.4 Network Configuration

61 EKI-1528/1526 User ManualChapter 5 Web-Based Configuration5.7 Auto Warning (Alarm)You can set the e-mail server and SNMP Trap server in the Setting

Page 65 - 5.5 Port Configuration

EKI-1528/1526 User Manual 625.8 Change PasswordYou can change the serial device server password on here:Note! All new configurations will take effect

Page 66 - 5.6 Monitor

63 EKI-1528/1526 User ManualChapter 5 Web-Based ConfigurationIf you have set a password via the configuration utility or Telnet or serial console,when

Page 67 - 5.7 Auto Warning (Alarm)

Chapter 11 Introduction

Page 68 - 5.8 Change Password

EKI-1528/1526 User Manual 645.9 Import/Export Device SettingsYou can Import or Export the serial device server all setting as the “.conf” file format.

Page 69 - 63 EKI-1528/1526 User Manual

65 EKI-1528/1526 User ManualChapter 5 Web-Based Configuration5.10 RebootThe configuration will take effect after clicking “Save” button. But all confi

Page 70 - EKI-1528/1526 User Manual 64

EKI-1528/1526 User Manual 66

Page 71 - 5.10 Reboot

Chapter 66 Telnet/Serial Console Configuration

Page 72 - EKI-1528/1526 User Manual 66

EKI-1528/1526 User Manual 686.1 OverviewThe purpose of the Console Configuration is to help you manage your device in con-sole mode. One of the main f

Page 73 - Chapter 6

69 EKI-1528/1526 User ManualChapter 6 Telnet/Serial Console ConfigurationConnecting SuccessAfter connection the serial device server in Telnet console

Page 74 - 6.2 Telnet Console

EKI-1528/1526 User Manual 70Select the COM portConfirm that the console configuration works ok.COM Port SettingsTo connect the EKI-1500 serial device

Page 75 - 6.3 Serial Console

71 EKI-1528/1526 User ManualChapter 6 Telnet/Serial Console ConfigurationConnection SuccessAfter connecting the device in console mode, you can simply

Page 76 - EKI-1528/1526 User Manual 70

EKI-1528/1526 User Manual 72HelpYou might type the “help” command or press <Tab> twice to show the supportedcommand list.[Usage] help[Function]

Page 77 - 6.4 Command List

73 EKI-1528/1526 User ManualChapter 6 Telnet/Serial Console ConfigurationSystem[Usage] system[Function] Show firmware version, device name and descrip

Page 78 - EKI-1528/1526 User Manual 72

EKI-1528/1526 User Manual 21.1 OverviewThis manual provides the necessary information to use the EKI-1528 and EKI-1526.The Advantech EKI-1500 series o

Page 79 - 73 EKI-1528/1526 User Manual

EKI-1528/1526 User Manual 74[Usage] port nn or port all[Function] Show the “nn”th port or all ports information[Usage] port nn desc XXXX[Function] Set

Page 80 - [Usage] port nn desc XXXX

75 EKI-1528/1526 User ManualChapter 6 Telnet/Serial Console Configuration[Usage] port nn||all type 232|422|485 flow 0|1|2|3[Function] Set serial ports

Page 81 - 75 EKI-1528/1526 User Manual

EKI-1528/1526 User Manual 76[Usage] mvcom[Function] Show all serial ports mode and related information[Usage] mvcom nn|all[Function] Set the “nn”th or

Page 82 - EKI-1528/1526 User Manual 76

77 EKI-1528/1526 User ManualChapter 6 Telnet/Serial Console ConfigurationmdataShow and setup the Data mode[Usage] mdata[Function] Show all serial port

Page 83 - 77 EKI-1528/1526 User Manual

EKI-1528/1526 User Manual 78netShow and setup the Ethernet port configuration[Usage] net 1|2[Function] Show the first or second Ethernet port status a

Page 84 - EKI-1528/1526 User Manual 78

79 EKI-1528/1526 User ManualChapter 6 Telnet/Serial Console Configurationpassword[Usage] password new XXXX[Function] Set new password [XXXX: maximum 3

Page 85 - 79 EKI-1528/1526 User Manual

EKI-1528/1526 User Manual 80monitorShow the serial ports settings, statistic, and connected IP address[Usage] monitor port 1|2|…|16 setting[Function]

Page 86 - EKI-1528/1526 User Manual 80

81 EKI-1528/1526 User ManualChapter 6 Telnet/Serial Console ConfigurationFor more detailed setting for auto warning, please refer to chapter 3.7timeSh

Page 87 - 81 EKI-1528/1526 User Manual

EKI-1528/1526 User Manual 82[Usage] time[Function] Show the current time information[Usage] time YYYYMMDDhhmmss[Function] Modify the current time info

Page 88 - EKI-1528/1526 User Manual 82

Appendix AA Pin Assignments

Page 89 - Appendix A

3 EKI-1528/1526 User ManualChapter 1 Introduction1.3 Product Specifications1.3.1 LAN Compatibility: IEEE802.3, IEEE802.3u Speed: 10/100 Mbps, auto M

Page 90 - A.1 Pin Assignments

EKI-1528/1526 User Manual 84A.1 Pin AssignmentsA.1.1 RS-232 Pin AssignmentsA.1.2 RJ-45 Cable PIN AssignmentsA.1.2.1 1. RS-422A.1.2.2 2. RS-485Pin No.

Page 91 - Appendix A Pin Assignments

85 EKI-1528/1526 User ManualAppendix A Pin Assignments

Page 92

www.advantech.comPlease verify specifications before quoting. This guide is intended for referencepurposes only.All product specifications are subject