Advantech Intel PXA270 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour PC/postes de travail Advantech Intel PXA270. Advantech Intel PXA270 User manual [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 80
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
TPC-30/32 Series
Intel PXA270
Touch Panel Computer
with 3.5" QVGA TFT LCD
User Manual
Vue de la page 0
1 2 3 4 5 6 ... 79 80

Résumé du contenu

Page 1 - User Manual

TPC-30/32 Series Intel PXA270 Touch Panel Computer with 3.5" QVGA TFT LCDUser Manual

Page 2

TPC-30/32 Series User Manual xFigure 4.9:Reboot Machine ... 23Figure 4.10:Registry Saving Success ...

Page 3

xiA.2.4 IOCTL_WDT_GETTIMEOUT: ... 47A.2.5 IOCTL_WDT_SETTIMEOUT: ... 47A.2.6 IOCTL_WDT_RE

Page 4

TPC-30/32 Series User Manual xii

Page 5

2CHAPTER 1General InformationThis chapter gives background infor-mation for the TPC-30/32 series.Sections include:• Introduction• Specifications• L

Page 6

TPC-30/32 Series User Manual 2Chapter 1 General Information1.1 IntroductionThe TPC-30/32 series of touch panel computers consist of state-of-the-art

Page 7

3 Chapter 1 1.2.2 I/O Ports• 1 serial port: RS-232 or RS-485 for TPC-30 (default as RS-232) CAN-Bus for TPC-32 (RS-232 for debug mode sup

Page 8

TPC-30/32 Series User Manual 41.3 LCD Specifications1.4 Touchscreen Specifications1.5 Power• Input Voltage: 8 ~ 28 VDC• Maximum Current: 2.5 ATPC

Page 9 - Contents

5 Chapter 1 1.6 I/O Ports ArrangementTPC-30/32 panel computers provide 1 serial port, 1 Ethernet LAN port and 1 USB port. Figure 1.1: I/O Ports Arra

Page 10

TPC-30/32 Series User Manual 61.8 Dimensions and Cutout• Weight: 0.5 Kg• Dimensions (WxHxD): 121 x 85.5 x 26.5 mm (4.76" x 3.37" x 1.75&q

Page 11

2CHAPTER 2System SetupThis chapter provides a brief explana-tion for operating the TPC-30/32.

Page 12

TPC-30/32 Series User Manual iiCopyrightThe documentation and the software included with this product are copy-righted 2008 by Advantech Co., Ltd. All

Page 13 - General Information

TPC-30/32 Series User Manual 8Chapter 2 System SetupYou can quickly get up and running by following the step-by-step instructions below.1. Open the p

Page 14 - 1.2 Specifications

9 Chapter 2 3. Plug the power lines into the system power receptor. Thus the system will turn on.Figure 2.3: Power Line into the Po

Page 15 - 1.2.4 Safety and Environment

TPC-30/32 Series User Manual 10

Page 16 - 1.3 LCD Specifications

2CHAPTER 3System TuningSections include:• LCD Contrast Tuning• Touchscreen Calibration• Buzzer Setting

Page 17 - 1.7 Panel Mounting

TPC-30/32 Series User Manual 12Chapter 3 System Tuning3.1 LCD TuningThe display settings let you control the backlight. Backlight provides a screen

Page 18 - 1.8 Dimensions and Cutout

13 Chapter 3 3.2 Touchscreen CalibrationYou can calibrate the touchscreen through “Start” ‡ “Setting” ‡ “Control Panel” ‡ “Stylus” as shown in the F

Page 19 - System Setup

TPC-30/32 Series User Manual 14Figure 3.5: Touchscreen Calibration3.3 Buzzer SettingTPC-30/32 panel computers provide a buzzer setting in Windows CE.

Page 21 - 9 Chapter 2

TPC-30/32 Series User Manual 16

Page 22

2CHAPTER 4Windows CESections include:• TPC Utilities• Networking• Application Program Development

Page 23 - System Tuning

iiiProduct Warranty (2 years)Advantech warrants to you, the original purchaser, that each of its prod-ucts will be free from defects in materials and

Page 24 - Chapter 3 System Tuning

TPC-30/32 Series User Manual 18Chapter 4 Windows CEThe TPC-30/32 operator interface terminals are designed for Windows CE. Windows CE is a compact op

Page 25 - 3.2 Touchscreen Calibration

19 Chapter 4 4.1 TPC UtilitiesThere are several utilities built into Windows CE in the TPC series.4.1.1 Soft-KeyboardThe TPC-30/32 series also has a

Page 26 - 3.3 Buzzer Setting

TPC-30/32 Series User Manual 20General Page This page displays the basic system information. There are two main parts: system and memory. The system s

Page 27 - 15 Chapter 3

21 Chapter 4 You can get more detailed IP information through “Advanced Network”. The information contains the default gateway, DHCP server, WINS and

Page 28

TPC-30/32 Series User Manual 22Only when you select a time span and enable the watchdog, will the response time be effective. When the watchdog is ena

Page 29 - Windows CE

23 Chapter 4 Reboot: You can reboot TPC-30/32 panel computers by clicking the “Reboot” button. Once this button is clicked, the dialog below will be

Page 30 - Chapter 4 Windows CE

TPC-30/32 Series User Manual 24Figure 4.10: Registry Saving SuccessFigure 4.11: Registry EditorWeb Server Root: Input the root path of the web server

Page 31 - 4.1 TPC Utilities

25 Chapter 4 4.1.3 Advantech ToolsThere are several useful tools in the Advantech program. Please go to “Start” ‡ “Programs” ‡ “Advantech” to run the

Page 32

TPC-30/32 Series User Manual 26Remote Display ApplicationRemote Display Application displays a Windows CE device screen on a remote desktop. It works

Page 33 - 21 Chapter 4

27 Chapter 4 Figure 4.14: Remote Display ApplicationFigure 4.15: Connect Once the connection is successfully established, you can see the display of

Page 34

TPC-30/32 Series User Manual ivCEThis product has passed the CE test for environmental specifications. FCC Class AThis equipment has been tested and f

Page 35 - 23 Chapter 4

TPC-30/32 Series User Manual 28Figure 4.16: Remote Display Host ApplicationNotepadPlusNotepadPlus is a text editor as shown in Figure 4.17.Figure 4.17

Page 36

29 Chapter 4 TPC Version Information shows the version information of the operation system in the TPC-30/32 as shown in Figure 4.18.Figure 4.18: TPC

Page 37 - 4.1.3 Advantech Tools

TPC-30/32 Series User Manual 30RegSave.exe [-s]:Saves registry settings. If you use “RegSave.exe –s”, no message box is displayed whether you are succ

Page 38

31 Chapter 4 2. A window that shows all available connections will pop up. Double click the icon that has the connection you want to configure. For e

Page 39 - Figure 4.16

TPC-30/32 Series User Manual 324. Select the “Name Server” tab.Figure 4.22: Setting Name Servers5. Press “Start” in of task bar of Windows and select

Page 40

33 Chapter 4 4.2.2 Network via Serial PortThis section introduces how to setup the connection between the TPC series and a host PC via Microsoft Acti

Page 41 - 4.1.4 Other Utilities

TPC-30/32 Series User Manual 34Click 'change...' to select the COM port- serial 1. In this example, we use COM1 of TPC to connect with COM

Page 42 - 4.2 Networking

35 Chapter 4 Figure 4.27: Change ConnectionYou can find the change is active. The connection is via serial1 - COM1.Figure 4.28: COM1 Set

Page 43 - 31 Chapter 4

TPC-30/32 Series User Manual 36Setting the Communication Environment of the HostDouble click the icon ActiveSync on your host computer.Figure 4.29: Mi

Page 44

37 Chapter 4 Configure the connection setting.Figure 4.31: Configure Connection SettingA window will pop up after you press “Get Connected”.Figure 4.

Page 45 - 4.2.2 Network via Serial Port

v12. Never open the equipment. For safety reasons, the equipment should be opened only by qualified service personnel.13. If one of the following situ

Page 46

TPC-30/32 Series User Manual 38Please run “repllog.exe” on the TPC.Figure 4.33: Run Repllog.exe on the TPCPress the “Next” button on your host compute

Page 47 - Figure 4.28: COM1 Set

39 Chapter 4 Select “Explore” in the Microsoft ActiveSync window, the window, Mobile Device, will pop up to display the file resources and informatio

Page 48

TPC-30/32 Series User Manual 404.3.2 Building Windows CE RuntimeBuild the Windows CE runtime with the eMbedded Visual tools. This section demonstrates

Page 49 - Figure 4.32: Get Connected

41 Chapter 4 Figure 4.37: Starting a New ProjectSelect “ADVTPC” in the main window of embedded Visual C++.Figure 4.38: SelectingNote The selected CPU

Page 50

TPC-30/32 Series User Manual 42After you complete the configuration procedure, you can start to develop your application. Press “Build” to compile yo

Page 51 - 39 Chapter 4

2 APPENDIX AWatchdog TimerProgramming

Page 52

TPC-30/32 Series User Manual 44Appendix A Watchdog Timer ProgrammingThere is a built-in watchdog timer in the TPC-30/32 series. You can access it thr

Page 53 - Figure 4.38: Selecting

45 Appendix A • lpInBuffer[in] Long pointer to a buffer that contains the data required to perform the operation. This parameter can be NULL if the

Page 54

TPC-30/32 Series User Manual 46A.2 How to Use the Control CodeThere are 6 control codes for the operation codes in the WDT driver.A.2.1 IOCTL _WDT_EN

Page 55 - Programming

47 Appendix A A.2.4 IOCTL_WDT_GETTIMEOUT:Gets the Watchdog time setting.lpInBuffer: unused.nInBufferSize: unused.lpOutBuffer: The DWORD pointer to yo

Page 56 - Appendix A Watchdog Timer

TPC-30/32 Series User Manual viWichtige Sicherheishinweise 1. Bitte lesen

Page 57 - 45 Appendix A

TPC-30/32 Series User Manual 48A.3 Examples#define WDT_CODE(ID) CTL_CODE(FILE_DEVICE_UNKNOWN, ID, METHOD_BUFFERED, FILE_ANY_ACCESS)#define IOCTL_WDT

Page 58 - A.2.3 IOCTL_WDT_STROBE:

49 Appendix A DWORD dwTemp;DWORD nIndex=2;// Set the Watchdog Timer as 10 seconds. Number 2 means 10 seconds.DeviceIoControl(m_hWDT, IOCTL_WDT_SET_TI

Page 59 - A.2.6 IOCTL_WDT_REBOOT:

TPC-30/32 Series User Manual 50

Page 60 - A.3 Examples

2 APPENDIX BFuse Specifications

Page 61 - 49 Appendix A

TPC-30/32 Series User Manual 52Appendix B Fuse SpecificationsB.1 Fuse SpecificationsRating: 125 VAC, 5ANote The fuse is set to break if the input vo

Page 62

2 APPENDIX CPin Assignments

Page 63 - Fuse Specifications

TPC-30/32 Series User Manual 54Appendix C Pin AssignmentsC.1 RS-232 Pin AssignmentsC.2 RS-485 Pin AssignmentPin No. DescriptionPin 1 DCDPin 2 RxPin

Page 64 - B.1 Fuse Specifications

55 Appendix C C.3 CAN-Bus Pin AssignmentsPin No. DescriptionPin 1 No ConnectionPin 2 CAN -Pin 3 No ConnectionPin 4 No ConnectionPin 5 GNDPin 6 No Co

Page 65 - Pin Assignments

TPC-30/32 Series User Manual 56

Page 66 - Appendix C Pin Assignments

2 APPENDIX DVisual Settings

Page 67 - C.3 CAN-Bus Pin Assignments

viiTechnical Support and AssistanceStep 1. Visit the Advantech web site at www.advantech.com/support where you can find the latest information about

Page 68

TPC-30/32 Series User Manual 58Appendix D Visual SettingsThere are two powerful and friendly utilities included to extend the visual capabilities of

Page 69 - Visual Settings

59 Appendix D Figure D.3: Change Font SettingFigure D.4: Small Font Display

Page 70 - Appendix D Visual Settings

TPC-30/32 Series User Manual 60D.2 Screen RotationPlease go to start->setting->control panel-> screen rotation as below.Figure D.5: Screen R

Page 71 - 59 Appendix D

61 Appendix D This screen is rotated 90 degrees in the example.Figure D.7: 90 Degrees RotationFigure D.8: Portrait Rotation

Page 72 - D.2 Screen Rotation

TPC-30/32 Series User Manual 62

Page 73 - Figure D.8: Portrait Rotation

2 APPENDIX ETPC-30T Update Guide

Page 74

TPC-30/32 Series User Manual 64Appendix E TPC-30T Update GuideE.1 Updating Image & BootloaderTo update the image & bootloader for the TPC-3

Page 75 - TPC-30T Update Guide

65 Appendix E Updating will take around 3 minutes. 3. After a successful update, the system will reboot and become black. 4. The system is initializi

Page 76

TPC-30/32 Series User Manual 666. The Boot Loader version can be checked at system power on stage.

Page 77 - 65 Appendix E

2 APPENDIX FCOM Port Settings

Page 78

TPC-30/32 Series User Manual viii

Page 79 - COM Port Settings

TPC-30/32 Series User Manual 68Appendix F COM Port SettingsThe serial port on the TPC-30T is adjustable. It can be set to RS-232, RS-485 or CAN-Bus.