Advantech PCL-740 Spécifications Page 23

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 29
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 22
20 PCL-740 User's Manual
BASE+4 Modem Control Register (MCR)
bit 0 DTR
bit 1 RTS
BASE+5 Line Status Register (LSR)
bit 0 Receiver data ready
bit 1 Overrun error
bit 2 Parity error
bit 3 Framing error
bit 4 Break interrupt
bit 5 Transmitter holding register empty
bit 6 Transmitter shift register empty
bit 7 At least one parity error, framing error or break
indication in the FIFO
BASE+6 Modem Status Register (MSR)
bit 0 Delta CTS
bit 1 Delta DSR
bit 2 Trailing edge ring indicator
bit 3 Delta received line signal detect
bit 4 CTS
bit 5 DSR
bit 6 RI
bit 7 Received line signal detect
BASE+7 Temporary data register
Vue de la page 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 29

Commentaires sur ces manuels

Pas de commentaire