60 AWS-8259 User's Manual
Voltage limit ranges: 5 V: 6.25 ±0.75 V
12 V: 14 ±1 V
-5 V: -6.25 ±0.75 V
-12 V: -14 ±1 V
Reset time: When the power supply has automatically shut down, and
the short circuit, over-current and/or over-voltage conditions have ceased
to exist, power will be automatically recycled to restart the power supply
within 3 seconds of such return to normal conditions.
No load start: When the power supply is switched on but with no load
connected, the power supply does not get damaged, and it is still com-
pletely safe for users.
Transient response: Dynamic load change: ±50% of maxi-mum
rating load Recovery time: 500 ms max.
Reliability Mean time between failures (MTBF): 100,000
hours minimum
Environmental specifications
Operating temperature: 0 ~ 50° C
Storage temperature: -40 ~ 60° C
Operating and storage humidity: 10 ~ 95% RH
Operating altitude: sea level ~ 15,000 ft
Storage altitude: sea level ~ 50,000 ft
International standards compliance
Safety: UL 1950
CSA 22.2 No. 234
TUV EN 60950
EMI: FCC Part 15 Subpart J Class B