UNO-3074 User Manual 22
2.6.2
Power On Configuration
Default configuration
after power on or
hardware reset is to set all the iso-
lated digital
output channels
to open status
(the current
of the load
cant be
sink) so
that users need
not
worry
about damaging
external devices during
system
startup or reset. When
the
system is hot reset, then
the status
of iso-
lated digital
output channels are selected by
jumper JP7. Table 2.10
shows
the configuration of
jumper JP7.
2.6.3
Isolated
Outputs
Each of isolated
output channels
comes equipped with a
Darlington tran-
sistor. All output
channels share common emitters.
Please note
that if
an external
voltage (5
~ 40
VDC) is applied to
an iso-
lated output
channel while it is being used as an output
channel, the cur-
rent will flow from
the external voltage source
to the UNO-3074. Please
take care that the
current through each
DO pin
not exceed 200
mA. Figure
2.7 below shows how
to connect
an
external
output load
to the UNO-3074
isolated outputs.
Please
note that
DO2 and DO3
may be configured
as
output pins of
Counter 0 and Counter
1 (please refer to section
2.7 for
more details)
Note: Please refer to Figure A.3 for location of JP7
Table 2.10: Digital Output Power On Configuration
JP7
Power on configuration after hot reset
Reset all digital output
(default configuration)
Keep last status after hot reset