University of Hertfordshire
30
The setting of the MDS command determines whether the trace data is transferred as
one or two 8-bit bytes.
TDF M
TDF M is the measurement data format. The measurement data format transfers trace
data in measurement units, and the measurement data can range from 32768 to
+32767.
TRA/TRB/TRC (Trace Data Input and Output): The TRA/TRB/TRC commands provide a
method for returning, storing or changing the 16-bit trace values.
TS (Take Sweep): Starts and completes one full sweep before the next command is
executed.
6.2 Sgpib Programming Commands
Sgpib programming commands are used to control GPIB card.
Working commands:
CMD <data>: Send raw multiline CMD with ATN set
DATA <data>: Send data or commands to GPIB divice.
END: Send '\n' (switch a new line) with EOI
EOI <val>: Send a byte with EOI
GET: Group Execute Trigger
IFC: Clear Interface
LISTEN <adr>: Switch the device on the address to LISTEN state