Page 1

INSTALLATION AND OPERATION MANUAL 200 WATT L-BAND TO C-BAND RACK-MOUNT SOLID STATE TRANSMITTER SSPB-3000C PM 150-50N4

Page 2 - WARRANTY

SSBP-3000C Page 9 Figure 1: Product Outline

Page 3 - CONTENTS

SSBP-3000C Page 10 3. MAJOR COMPONENTS AND THEIR FUNCTION This Section describes the major components and their functions within the SSPB unit. T

Page 4

SSBP-3000C Page 11 3. Any of the GaAs FET devices fails (current is out of range) 3.3 WAVEGUIDE ARM ASSEMBLY The Waveguide Arm Assembly contain

Page 5 - FIGURES

SSBP-3000C Page 12 3.5.1 FAULT DETECTION AND INDICATION The unit will automatically go into a shutdown mode and send a message to all of the exte

Page 6

SSBP-3000C Page 13 7. Current sensor. The main controller board also receives the +12 VDC low current from the power supply. The main power supp

Page 7 - 1. SAFETY

SSBP-3000C Page 14 Figure 2: SSPB Block Diagram HPA ASSEMBLYW/G ARM ASSEMBLYTEMPSENSOR+12V, -9V+12V, -9VOUTPUTPOWERDETECTOR40 dBCIRCULATORLNACON

Page 8

SSBP-3000C Page 15 TABLE 1: FRONT PANEL CONTROLS AND INDICATIONS Control/display Function ENTER Select menu line, select item for modification or

Page 9 - 2. GENERAL INFORMATION

SSBP-3000C Page 16 Figure 3: Front Panel Assembly

Page 10 - SSBP-3000C

SSBP-3000C Page 17 3.9 ELECTRICAL SPECIFICATIONS The electrical specifications for the SSPB are listed in TABLE 2. TABLE 2: ELECTRICAL SPECIFICAT

Page 11

SSBP-3000C Page 18 4. INTERFACES The SSPB provides four user interfaces that could be used to connect to several optional external devices. The

Page 12

SSBP-3000C Page 1 WARRANTY This ADVANTECH Advanced Microwave Technologies Inc. product is warranted against defects in material and workmanship fo

Page 13

SSBP-3000C Page 19 TABLE 3: DISCRETE INTERFACE (J3) RELAY – PIN ASSIGNMENTS Pin Description 1 TX_MUTE (External MUTE Command) If pin 1 (MUTE COMM

Page 14

SSBP-3000C Page 20 4.3 RS-485 INTERFACE This serial communication interface provides for the user, access to all of the monitor and control functi

Page 15

SSBP-3000C Page 21 Figure 4: 1:1 Redundant System UNIT "A"J1J7J6-1UNIT "B"J1 J7J6-1 SPLITTERIF INPUT(TYPE

Page 16 - Control/display Function

SSBP-3000C Page 22 5. UNPACKING AND INSTALLATION This Section contains instructions for the site preparation, unpacking and installation of the S

Page 17

SSBP-3000C Page 23 TABLE 6: CONNECTORS Connector Function Description Mating Connector (J1) RF IN L-Band Input N-Type (F) N-Type (M) (J2) RS2

Page 18

SSBP-3000C Page 24 Figure 5: Connectors Location on Front and Back Panels

Page 19 - 4. INTERFACES

SSBP-3000C Page 25 5.3.1 ENVIRONMENTAL AND ADEQUATE VENTILATION CONSIDERATIONS The SSPB contains a forced air cooling system, which prevents the

Page 20 - Pin Description

SSBP-3000C Page 26 1. Using the proper mounting hardware and the non-pivoting slide kit (see TABLE 20 at page 46), install the SSPB on to the rack

Page 21

SSBP-3000C Page 27 5.3.3.3 RS-232 Interface 1. If it is desired to use the RS-232 terminal mode, then construct an interconnecting cable by using

Page 22

SSBP-3000C Page 28 d. Connect the AC power cable to AC Line port of the SSPB and the AC power source. TABLE 9: POWER REQUIREMENTS Power Require

Page 23

SSBP-3000C Page 2 CONTENTS 1. SAFETY...

Page 24

SSBP-3000C Page 29 6. PRE-POWER AND SYSTEM CHECKOUT This Section describes the pre-power procedure for the SSPB and an initial checkout of the sy

Page 25

SSBP-3000C Page 30 7. OPERATION 7.1 INTRODUCTION This Section describes the normal operation of the SSPB in a stand-alone configuration. The de

Page 26 - CAUTION:

SSBP-3000C Page 31 6. Ensure that the L-Band input signal is being applied to the L-Band In port of the unit. 7. Allow the SSPB to warm up for

Page 27

SSBP-3000C Page 32 sub-menu. Press the [Enter] key a second time to switch between the two sub-menus. Press the [CLEAR] key to return to the ‘Sys

Page 28

SSBP-3000C Page 33 Figure 6: Front Panel Sequence Pwr = 42.1 dBmRS-485 9600;N;8;1Pwr = 42.1 dBmSSPB INFORMATIONPwr = 42.1 dBmTemp=+48.2oCPwr = 42

Page 29 - ONNECTIONS

SSBP-3000C Page 34 7.6 USING THE SSPB SOFTWARE The RS-232 and the RS-485 interfaces provide the serial communication between the user’s monitoring

Page 30 - WARNING: The

SSBP-3000C Page 35 Figure 7: RS-232 Communication via HyperTerminal

Page 31 - WARNING:

SSBP-3000C Page 36 TABLE 11: RS-232 MENU ITEM DEFINITION Item Description S/N: Serial Number of the SSPB unit (B2309, in this case) Soft: Versio

Page 32

SSBP-3000C Page 37 Figure 8: Help function in HyperTerminal

Page 33

SSBP-3000C Page 38 TABLE 12: COMPUTER TERMINAL COMMANDS FOR RS-232 INTERFACE Command Description Response h Help function Provides the list of c

Page 34

SSBP-3000C Page 3 8.1 PREVENTIVE MAINTENANCE...

Page 35

SSBP-3000C Page 39 TABLE 12: COMPUTER TERMINAL COMMANDS FOR RS-232 INTERFACE (continued) Command Description Response sst Status Displays the s

Page 36

SSBP-3000C Page 40 8. MAINTENANCE This Section describes scheduled maintenance procedure for the SSPB. 8.1 PREVENTIVE MAINTENANCE This produc

Page 37 - Item Description

SSBP-3000C Page 41 9. RS-485 SERIAL COMMUNICATION PROTOCOL The protocol described in this Section is used for the interconnection between the SSP

Page 38

SSBP-3000C Page 42 9.2 COMMANDS The following commands are sent from master to slave (Master is a PC, a Control Panel or any Network Management Sy

Page 39

SSBP-3000C Page 43 9.3 RESPONSE TO COMMANDS FROM SLAVE TO MASTER 9.3.1 CONDITION STATUS RESPONSE TABLE 14: RESPONSE FRAME STRUCTURE BitNo 2th byt

Page 40

SSBP-3000C Page 44 9.3.3 READ FREQUENCY RANGE RESPONSE TABLE 16: READ FREQUENCY RANGE RESPONSE Bit No 2nd byte 3rd byte 4th byte 5th byte 6t

Page 41 - WARNING: Personnel per

SSBP-3000C Page 45 9.3.5 UNIT STATUS AND POSITION RESPONSE TABLE 18: UNIT STATUS AND POSITION RESPONSE Bit No 2nd byte 3rd byte 4th byte 5th b

Page 42

SSBP-3000C Page 46 10.PACKING LIST Single unit Shipping Kit P/N 195-50N415-0G1 TABLE 20: PACKING LIST Item Quantity Description Part # 1. 1 I

Page 43

SSBP-3000C Page 47 RMR-C300L Redundancy Kit P/N 190-500405-0C0 TABLE 21: REDUNDANCY KIT Item Quantity Description Part Number 1. 1 Flex Wavegui

Page 44

SSBP-3000C Page 48 11.APPENDIX A: SAFETY AND EMC COMPLIANCE Advantech Products are compliant with the following standards: SAFETY: IEC 950 (1992)

Page 45

SSBP-3000C Page 4 FIGURES FIGURE 1: PRODUCT OUTLINE...

Page 46

SSBP-3000C Page 49 Figure 9: Redundant System (rear view)

Page 47

SSBP-3000C Page 50 Figure 10: Redundant System (lateral right view)

Page 48

SSBP-3000C Page 51 Figure 11: Redundant System (lateral left view)

Page 49

SSBP-3000C Page 52 Figure 12: Redundant System (top view)

Page 50

SSBP-3000C Page 53 Figure 13: RS-232 Communication via HyperTerminal for Redundant System

Page 51

SSBP-3000C Page 54 Figure 14: Proposed Graphic User Interface for a Redundant System based on RS-485 Packet Protocol

Page 52

SSBP-3000C Page 5 TABLES TABLE 1: FRONT PANEL CONTROLS AND INDICATIONS ...15 TABLE 2: ELECTRICAL

Page 53

SSBP-3000C Page 6 1. SAFETY To prevent the risk of injury to personnel or loss related to equipment malfunction, ADVANTECH uses the following sym

Page 54

SSBP-3000C Page 7 Incorporate the terminations prior to applying prime power to the transmitter. This procedure prevents self-oscillation and irra

Page 55

SSBP-3000C Page 8 2. GENERAL INFORMATION 2.1 INTRODUCTION The ARMU-LC200-BRN , part of the SSPB-3000C family, is a 200-Watt L-Band to C-Band Sol