C.12 Calibration parameter strobe — BASE+18H
Write any values to BASE+18H after finished the calibration procedure, to save
all the D/A channels’ parameter into the EEPROM.
Table C-11 Register for calibration parameter strobe
Base Addr.
151413121110987654321 0
Calibration parameter strobe
18H W
XXXXXXXXXXXXXXXX
Note:
Once you want to calibrate the range of the specific channel, be sure to
write the value to BASE+14H first. Next, write the data to BASE+1EH
for calibration purpose. Last, to write the value to this register to strobe
the parameter into EEPROM.