5-8
ADAM 4000 Series User’s Manual
4011, 4011D, 4012, 4013, 4015, 4015T, 4016,
4017, 4017+, 4018, 4018+, 4018M, 4019+
Input Range Code (Hex) Input Range for 4019+
02 ± 100 mV
03 ± 500 mV
04 ± 1 V
05 ± 2.5 V
07 +4~20mA
08 ± 10 V
09 ± 5 V
0D ± 20 mA
0E
Type J Thermocouple 0 ~ 760 ℃
0F
Type K Thermocouple 0 ~1370 ℃
10
Type T Thermocouple -100 ~ 400 ℃
11
Type E Thermocouple 0 ~ 1000 ℃
12
Type R Thermocouple 500 ~ 1750 ℃
13
Type S Thermocouple 500 ~ 1750 ℃
14
Type B Thermocouple 500 ~ 1800 ℃
Table 5-2 Baud Rate Codes
Baud Rate Code (Hex) Baud Rate
03 1200 bps
04 2400 bps
05 4800 bps
06 9600 bps
07 19.2 kbps
08 38.4 kbps