4.4.3 AOScale
Scales a voltage to a binary value that, when written to one of the analog output channels, produces
the specified voltage.
Input:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
Channel The channel number of a specified device
Voltage The voltage value needing to be changed to be
a binary value.
Output:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
Va lu e Binary output value scaled from input voltage.