4.8.7 FAITransfer
Transfers the data from the buffer being used for the data acquisition operation to the specified data
buffer.
Input:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
DisplayBuffer A cluster containing HalfBufSize, VoltageBuf,
BinaryBuf
error in A cluster containing error information, such as the
status, code, and source elements that is passed from
a previous linked VI.
Output:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
DisplayBuffer A cluster containing HalfBufSize, VoltageBuf,
BinaryBuf
Overrun Overrun status: overrun (1), no overrun (0)
error out A cluster containing error information. If error in
indicated an error, the status, code, and source
elements of error out have the same values as the
corresponding elements of error in