4.6.5 QCounterStart
Configures the specified counter for an event-counting operation and starts the counter. This
function only supports PCL-833.
Input:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
Counter Counter number of the specified device.
InputMode Input mode control : DISABLE(0),
ABPHASEX1(1), ABPHASEX2(2),
ABPHASEX4(3), TWOPULSEIN(4),
ONEPULSEIN(5)
error in A cluster containing error information, such as the
status, code, and source elements that is passed from
a previous linked VI.
Output:
Data type
Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
error out A cluster containing error information. If error in
indicated an error, the status, code, and source
elements of error out have the same values as the
corresponding elements of error in