Advantech PCI-1710 Guide de l'utilisateur Page 141

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 199
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 140
4.6 adCountTimer
4.6.1 CounterEventStart
Configures the specified counter for an event-counting operation and starts the counter.
Input:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program..
Counter Counter number of the specified device.
GateMode Gating mode to be used for AMD Am9513A
error in A cluster containing error information, such as the
status, code, and source elements that is passed from
a previous linked VI.
Output:
Data type
Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program..
error out A cluster containing error information. If error in
indicated an error, the status, code, and source
elements of error out have the same values as the
corresponding elements of error in
Vue de la page 140
1 2 ... 136 137 138 139 140 141 142 143 144 145 146 ... 198 199

Commentaires sur ces manuels

Pas de commentaire